Info & pricing
570-538-7200
tpsinfo@tps.spx.com
|
|
1700° Crucible Furnaces, Independent
Control, Temperature Range 500°C to 1700°C,
5,000 Watts
| Model |
Controller |
Voltage,
Hz |
Vestibule
Top Opening
ID in"(mm) |
Vestibule
Bottom
Opening
ID in" (mm) |
Working
Depth
ID in"(mm) |
Exterior
Dimensions
WXDXH in"(mm) |
Ship
Weight
lbs (kg) |
| CF56724C |
CC59256PCOMC |
208/240V,
50/60Hz |
6.5"(165mm)2 |
5"(127mm) |
6.5"(165mm) |
19.5"(495)x20"(508)
x35.5"(902) |
250(114) |
Notes:
- Power cord and interconnecting wiring supplied by customer.
- Maximum weight capacity is 0.5 pounds per square inch of interior
floor surface.
- Actual performance may vary depending on load, chamber size,
sample placement, ambient temperature and environmental conditions.
Controllers
1700°C Controller, Programmable, With
Communications
Lindberg/Blue M 1700°C Programmable Controller provides 300
programmable segments for a variety of ramp (up and down) and dwell
(timed holds) settings. Controller will accept up to 30 individual
programs with up to 99 segments per program. The controller visually
displays ramp rate, dwell time, program segment and percent power
output. A holdback feature allows the operator to set a process
vs. setpoint" temperature value which, when exceeded, holds the
program to allow the process to catch up.
The controller includes an advanced self-tuning feature which
automatically sets the best PID settings (proportional, integral,
derivative) for the thermal process. Two digital displays simultaneously
indicate actual temperature and setpoint temperature. High limit
overtemperature protection is standard. The control console includes
a circuit breaker, power module, transformer and cooling fans.
Controllers include RS485 data port (communications card and port)
for connection to remote computer, allowing modification, interrogation
and data transfer of all instrument control and configuration parameter.
Up to 30 units can be connected to one PC. Software is not included,
but is available as an option.
Option B Overtemperature Control (OTC)
Adjustable digital overtemperature control, factory installed on
selected control consoles with "B" designation; see chart. Protects
furnace and load in the event of primary control circuit failure.
Overrides main controller, assumes temperature control and shuts
off power to furnace if high limit is reached. Manual re-set
required for safety. Operates via signal from independent thermocouple.
Model |
CC59256PCOMC |
CC59256PBCOMC |
Digital |
|
|
With
Programmer |
|
|
With
Overtemp Control |
|
|
Electrical
Volts, Hz |
208/240V,
50/60Hz |
208/240V,
50/60Hz |
Exterior
Dimensions
WxDxH in" (mm) |
21"(533)x15"(381)
x10"(254) |
21"(533)x15"(381)
x10"(254) |
Ship
Weight
lbs (kg) |
130(59) |
130(59) |
Heat-Up/Cool-Down Rates
|